Published on

Montrose Partners with Thermo Fisher Scientific for Real Time EtO Monitoring Solutions

Authors
  • avatar
    Name
    Ambient Authority
    Twitter

Montrose, a leading environmental consulting firm, has partnered with Thermo Fisher Scientific to offer innovative EtO monitoring solutions that meet EPA standards. This collaborative effort enables real-time tracking of ethylene oxide levels, ensuring compliance with regulatory requirements.

What is the purpose of the partnership between Montrose and Thermo Fisher Scientific?

The purpose of the partnership between Montrose and Thermo Fisher Scientific is to provide real-time ethylene oxide (EtO) monitoring solutions that meet recently proposed EPA standards.

How secure is the system used in real-time EtO monitoring solutions?

The system used in real-time ethylene oxide (EtO) monitoring solutions provides robust security measures to ensure accurate and reliable data collection. This includes advanced encryption techniques, secure communication protocols, and strict access controls to prevent unauthorized access or tampering with the system's data and configuration.

How does the MAX-iAQ™ OE-FTIR system detect EtO even in high humidity environments?

The MAX-iAQ™ OE-FTIR system detects EtO even in high humidity environments using its advanced StarBoost™ technology, which enables it to quantify EtO to a detection limit of 1 ppb while maintaining short cycle times.

Can the MAX-iAQ™ OE-FTIR system operate as a continuous monitor with little to no user interaction?

Yes, the MAX-iAQ™ OE-FTIR system is designed to operate as a continuous monitor with little to no user interaction.

What technology provides Indoor Air Quality monitoring in the combined solution?

The MAX-iAQ™ OE-FTIR (StarBoost™) technology from Thermo Scientific provides Indoor Air Quality monitoring in the combined solution.

How does Thermo Fisher Scientific's real-time EtO monitoring solution work?

Thermo Fisher Scientific's real-time Ethylene Oxide (EtO) monitoring solution utilizes a combination of advanced sensors and proprietary algorithms to continuously monitor EtO levels in real-time. This solution leverages proven gas chromatograph technology to detect and quantify EtO with high accuracy, enabling facilities to quickly respond to changes in EtO concentrations and ensure compliance with regulatory limits.

What are the key components of the turnkey solution and how do they function together?

The turnkey solution for monitoring ethylene oxide (EO) comprises several key components that work in tandem to provide a comprehensive monitoring system. The primary components include EO sensors, data loggers, and software analytics tools. These components are designed to collect and analyze real-time EO concentration readings, alerting operators when levels exceed safe thresholds. The sensors continuously monitor the air for EO concentrations, transmitting data to the data loggers for storage and processing. The software analytics tool then interprets this data, providing actionable insights and notifications to ensure operator safety and compliance with regulatory requirements.

Can the system be integrated with existing manufacturing processes or systems?

The turnkey solution for monitoring ethylene oxide (EtO) can seamlessly integrate with existing manufacturing processes and systems to ensure a streamlined monitoring experience. This integration allows users to leverage their current infrastructure, minimizing disruptions and maximizing efficiency in EtO detection and management.

How does the system handle false positives or alarm fatigue?

The turnkey solution for monitoring ethylene oxide employs advanced algorithms and machine learning techniques to minimize false positive alarms. It achieves this by continuously analyzing data from multiple sources, including sensors, laboratory results, and historical trends, to accurately identify potential issues and reduce noise in the system. This approach helps to eliminate alarm fatigue, allowing operators to focus on legitimate alarms and take prompt corrective action.

What kind of training or support is provided for users of the system?

Our turnkey solution for monitoring ethylene oxide offers comprehensive training and support to ensure a seamless user experience. This includes interactive tutorials, video demonstrations, and online documentation, as well as access to our dedicated technical support team and regular software updates to maintain optimal system performance.

What is the LOD of standard GC systems?

The LOD (Limit of Detection) of standard GC (Gas Chromatography) systems is typically 50 ppb.

How does the LOD compare to other analytical methods?

The Limit of Detection (LOD) for GC systems typically at 50 parts per billion (ppb), which suggests that this method has a relatively high sensitivity and ability to detect low concentrations of target analytes. In comparison, other analytical methods such as liquid chromatography-tandem mass spectrometry (LC-MS/MS) may have LODs in the range of 1-10 ppb for certain applications, while others like gas chromatography-mass spectrometry (GC-MS) may have LODs ranging from 0.01 to 100 ppb depending on the specific instrument and analytical conditions.

Can GC systems be used for real-time monitoring?

GC systems typically require a relatively short analysis time of minutes, which suggests that they are more suited for batch analyses rather than real-time monitoring applications where results are typically required in seconds or milliseconds.

What types of equipment are used for real-time EtO monitoring?

Real-time EtO (ethylene oxide) monitoring in facilities and chemical plants subject to 40 CFR Part 63 regulations typically employs gas detectors or monitors that utilize various technologies such as colorimetric, electrochemical, or infrared sensors. The most common types of equipment used for real-time EtO monitoring include personal dosimeters, fixed-site monitors, and portable gas detectors, which provide instant readings of EtO concentrations in the air.

Is etidate a suitable alternative to ethylene oxide (EtO) gas?

The Proposed Interim Decision (PID) for sterilization facilities does not explicitly mention etidate as an approved alternative to ethylene oxide (EtO) gas. However, according to 40 CFR Part 63, etidate has been identified as a suitable alternative to EtO in certain sterilization applications due to its comparable sterilization efficacy and reduced toxicity concerns.

How can facilities reduce their EtO emissions?

Facilities subject to 40 CFR Part 63 and chemical plants can reduce EtO (ethylene oxide) emissions by implementing controls such as scrubbers, carbon filters, and activated carbon beds. Additionally, proper housekeeping practices, including frequent cleaning and maintenance of equipment and processes, can also help minimize EtO emissions. Furthermore, facilities can consider implementing emission reduction technologies, such as thermal oxidation systems or catalytic oxidizers, to further reduce EtO emissions.

What are the long-term health effects of exposure to EtO gas?

According to 40 CFR Part 63, exposure to ethylene oxide (EtO) gas has been linked to various long-term health effects, including myelodysplastic syndrome and acute myeloid leukemia. The Proposed Interim Decision for sterilization facilities also notes that repeated or prolonged exposure to EtO can increase the risk of developing these conditions. Additionally, studies have shown that workers exposed to EtO at concentrations above 1 ppm may experience increased risks of developing lymphoma and other cancers.

Are there any alternatives to EtO sterilization that can reduce emissions and improve worker safety?

The Proposed Interim Decision (PID) for sterilization facilities presents alternatives to Ethylene Oxide (EtO) sterilization, which can reduce emissions and improve worker safety. One such alternative is hydrogen peroxide gas plasma sterilization, which has been demonstrated to be effective in reducing EtO emissions by up to 90%. Additionally, the PID suggests that other alternatives, such as vaporized hydrogen peroxide, peroxyacetic acid, and ozone, may also offer similar benefits. These alternatives can help mitigate the environmental and occupational hazards associated with EtO sterilization, while maintaining high levels of sterility and safety in medical facilities.

How does the EMS-10 system compare to traditional gas chromatograph-based systems?

The EMS-10 system outperforms traditional gas chromatograph-based systems in terms of speed, sensitivity, and cost-effectiveness. While traditional systems typically require longer cycle times, are less sensitive in detecting compounds at low concentrations, and incur higher maintenance costs, the EMS-10 utilizes advanced FTIR spectral analysis and Thermo Scientific™ StarBoost™ Technology to quantify 10-100+ compounds down to single digit ppb while maintaining short cycle times, making it a more attractive alternative.

Questions? Need Assistance?

We can help with your air quality monitoring needs. Contact Us.